Product Details:
Voltage | 240 V AC |
Sampling Rate | 0.2 s |
Alarm Output | 1 or 2 (option) |
Weight | approx. 100 g |
Frequency | 60 Hz |
Power consumption | More Than Equal 5 VA (at 100 V) or More Than Equal 6 VA (at 220 V) |
Display | 7-segment 4-digit LED |
Dimensions | 48 (W) x 48 (H) x 62 (D) mm |
Ambient Temperature | -10 Deg C to +55 Deg C |
Product Details:
Model Name/Number | PXR3 |
Voltage | 240 V AC |
Operating Relative Humidity | RH90% or less (non condensation) |
Weight | approx. 150 g |
Measurement cycle | more Than 0.5 s |
Resolution | 1 Deg C |
Frequency | 60 Hz |
Operating Environment | -10 Deg C to +50 Deg C |
Dimensions | 24 x 48 x 85 mm |
Product Details:
Weight | Approx. 3 Kg |
Component and Range | 20% |
Repeatability | +-0.5% FS |
Zero Drift | +-10% FS per 6 months |
Output Signal | 20 mA DC |
Dimensions | H 257 x W 220 x D 85 mm |
Product Details:
Power | 50 VA |
Temperature | 0 Deg C to 40 Deg C |
Flow Rate | 0.5 L / min +- 0.2 L / min |
Voltage | 100 to 240 V AC |
Frequency | 50 / 60 Hz |
Outside Dimension | 211 (H) x 218 (W) x 257 (D) mm |
Mass | 5 Kg |
Pressure | 5 kPa or lower |
Continuous measurement of CO, CO2, CH4 in heat treatment furnace. Simultaneously and continuously measures concentrations of 2 different gases.
Other Detail:
CP (Carbon Potential) calculation available (option)
Single-beam system: long-term stability and low maintenance
Simultaneous and continuous measurement of 2 different gases
Compact and lightweight
Product Details:
Response Time | More Than Equal 60 s |
Weight | Approx. 16 kg |
Current | 250 VA |
Zero Drift | +-1.0% FS per week (+-2% FS per week for 100-200 ppm range) |
Span Drift | +-2.0% FS per week |
Dimensions | H 835 x W 218 x D 202 mm |
Voltage | 100-240 V AC |
Frequency | 50/60 Hz |
Repeatability | +-0.5% FS |
ZKJ7 is the substitute for the obsoleted model ZRG. Size and terminal allocation are designed same with ZRG for ease of replacement.
Simultaneously and continuously measures up to 3 components among NO, SO2, CO, CO2, CH4, and O2
Hardly affected by interference from other gases
Optional functions include: automatic calibration, O2 correction, averaging, concentration alarm, remote range-switching, and more.
Easy-to-see backlit LCD
Product Details:
Model Name/Number | PXR3 |
Weight | approx. 150 g |
Humidity | RH90% or less (non condensation) |
Dimensions | 24 x 48 x 85 mm |
Operating Environment | -10 Deg C to +50 Deg C |
Voltage | 240 V AC |
Frequency | 60 Hz |
Resolution | 1 Deg C |
Measurement Cycle | More Than 0.5 s |
Product Details:
Response Time | 30 s |
Weight | Approx. 11 kg |
Humidity | RH90% |
Span Drift | +-2.0% FS per week |
No of Ranges | Up to 2 ranges per component |
Repeatability | more Than Equal +-0.5% FS |
Linearity | More Than Equal +-1% FS |
Operating Environment | 5 to +45 Deg C |
Voltage | 240 V AC |
Frequency | 50/60 Hz |
Power consumption | Approx. 100 VA |
Dimensions | 133 (H) x 483 (W) x 382 (D) mm |
Product Details:
Power Consumption | Approx. 47 VA |
Voltage | 240 V AC |
Frequency | 50/60 Hz |
Number of Inputs | 9 or 18 points |
Measurement cycle | 100 ms |
Display | 5.7 Inch |
Recording Capacity | 2 GB max |
Indication Accuracy | +- 0.15% + 1 digit of input range |
Indication Resolution | 0.1 Deg C |
Compact front panel Up to 6 channels for thermocouples, RTD, voltage, or current input
Data saving on CompactFlash
Data viewer and parameter loader software provided as standard
Ethernet (option)
Lithium-ion battery driven version available
Quick search and display of past data
3 or 6 input channels
Product Details:
Voltage | 240 V AC |
Frequency | 60 Hz |
Power consumption | Approx. 47 VA |
Number of inputs | 9 or 18 points |
Measurement Cycle | 100 ms |
Display | 5.7 Inch |
Recording Capacity | 2 GB max. |
Open Collector Output | 18 points (option) |
Indication Resolution | 0.1 Deg C |
Product Details:
Voltage | 240 V AC |
Frequency | 50 Hz |
Power Consumption | Approx. 47 VA |
Number of inputs | 9 or 18 points |
Measurement cycle | 100 ms |
Life of backlight | 50,000 hours |
Display | 5.7 Inch |
Recording Capacity | 2 GB max |
Indication resolution | 0.1 Deg C |
Product Details:
Flow Range | 50 mm |
Frequency | 50 Hz |
Voltage | 240 V |
Ambient Humidity | More Than Equal RH 90% |
Ambient Temperature | -40 Deg C to +60 Deg C |
Enclosure | IP 66 |
Power consumption | Approx. 20 VA |
Product Details:
Accuracy | +-1% |
Pipe Diameter | 50-1200 mm |
Fluid Temperature | -40 Deg C to 20 Deg C |
Response | 0.2 seconds |
Ambient Temperature | -20 Deg C to +55 Deg C |
Analog Output | 4-20 mA DC |
Dimension | H170 x W142 x D70 mm |
Product Details:
Usage/Application | Automotive |
Accuracy | (+/-): 0.5% of reading |
Analog Output | 4-20 mA DC |
Response | 0.2 seconds |
Ambient Temperature | -20 Deg C to +55 Deg C |
Dimensions | H220 x W230 x D95 mm |
Fluid Temperature | -40 Deg C to 20 Deg C |
Flow transmitter: FSVL
Detector: FSS
Product Details:
Response Time | More Than Equal 60 s |
Power | 250 VA |
Humidity | RH90% |
Span Drift | +-2.0% FS per week |
Repeatability | +-0.5% FS (+-1% FS for 50 ppm or less) |
Linearity | +-1% FS |
Operating Environment | -5 to +45 Deg C |
Voltage | 100-240 V AC |
Frequency | 50/60 Hz |
Dimensions | 483 (H) x 177 (W) x 600 (D) mm |
Simultaneous and continuous measurement of up to 5 components among:
NO, SO2, CO2, CO, CH4, N2O, and O2
Ideal for flue gas monitoring in incinerators and industrial furnaces
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Easy-to-see LCD
Zero drift for 200 ppm range: ≤ ±1% FS per week
Product Details:
Response Time | More Than Equal 30 s |
Weight | Approx. 7 kg |
Power | 100 VA |
Zero Drift | +-2.0% FS per week |
Dimensions | H 133 x W 483 x D 382 mm |
Voltage | 240 V AC |
Frequency | 50/60 Hz |
Repeatability | +-0.5% FS |
ZPAH and ZPA1 are substitutes for the obsoleted model ZRH. Size and terminal allocation are designed same with ZRH for ease of replacement.
Continuously measures SO2, CO, CO2, CH4, or CO+CO2
Hardly affected by interference from other gases
Optional functions include: automatic calibration, remote range-switching, rage identification output, and more.
Easy-to-see backlit LCD
Product Details:
Response Time | More Than Equal 10 s (for 90% response) |
Reproducibility | +-0.5% FS |
Linearity | +-2% FS |
Voltage | 115 V AC |
Frequency | 50/60 Hz |
Gas temperature | -20 Deg C to +600 Deg C |
Gas pressure | -3 kPa to +3 kPa |
Continuous measurement of O2 in flue gas from industrial boilers or furnaces. Ideal for combustion control
Fast response
Low maintenance
A variety of inputs and outputs
Easy to operate
Product Details:
Weight | Approx. 350 kg |
Voltage | 100 V AC |
Frequency | 50/60 Hz |
Power consumption | Approx. 1 kVA (Max. 1.5 kVA) |
Ambient temperature | 15 to 30 Deg C |
Ambient humidity | 30 to 75% RH |
Dimensions | 640 x 1740 x 828 mm |
Real-time, quantitative measurement of aerosol (PM2.5) in the air
Real-time monitoring
Simultaneous and quantitative analysis of particle size, number of particles, and composition
High accuracy ensured by a combination of multiple principles
Easy-to-use touch screen
Product Details:
Zero Drift | +-1.0% FS max./week |
Repeatability | +- 0.5% FS |
Linearity | +-1.0% FS max |
Dimensions | 1710(H)x800(W)x615(D) mm |
Mass | About 300 kg |
Ambient conditions | -5 to + 40 Deg C |
Voltage | 230 V |
Frequency | 50 Hz |
Continuous monitoring of 5 components:
NOx, SO2, CO, CO2, and O2
Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Simultaneous and continuous measurement of up to 5 components
Sample switching system ensures zero-point stability
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Japanese type approval
Product Details:
Weight | Approx. 500 Kg |
Power | approx. 1200 VA |
Span Drift | +-2.0% FS per week |
Repeatability | +-0.5% FS |
Gas Sampling Amount | Approx. 2 L/min |
Dimensions | 1215 (W) x 700 (D) x 1780 (H) mm |
Frequency | 50 Hz |
Voltage | 230 V |
Continuous monitoring of 7 components:
NOx, SO2, CO, CO2, O2, HCl, and dust
Ideal for environmental monitoring
Space-saving design
All the necessary equipment are housed in a cabinet.
Less electrical work: signal and power terminals are in one place
Maintenance-free HCl measurement
Japanese type approval (NOx, SO2, CO, O2)
Saves power by 40% compared to conventional models
Product Details:
Weight | 10 Kg |
Voltage | 100-240 V AC |
Frequency | 50/60 Hz |
Power Consumption | 80 VA |
Dimensions | 400 x 180 x 155 mm |
IP Rating | IP65 |
Continuous monitoring of HCl, NH3, CO, CO2, CH4, and O2
Low maintenance
Low operating-cost??? with no gas-sampling device and few parts to be replaced
Superior long-term stability
Fast response within 2 seconds
Tolerant to high temperature and high dust
Environment friendly: 80 VA, low power consumption
Analog output for transmittance is available
Compliant with RoHS directive (2011/65/EU)
Double-beam version for CO and O2 measurement available
Product Details:
Humidity | 90% RH |
Repeatability | +-0.5% FS |
Linearity | +-1.0% FS max |
Dimensions | 1710 (H)x800 (W)x615 (D) mm |
Mass | About 300 Kg |
Ambient Conditions | -5 to +40 Deg C |
Voltage | 230 V |
Frequency | 50 Hz |
Power Consumption | 600 VA |
Continuous monitoring of up to 5 components:
NOx, SO2, CO, CO2, and O2
Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Japanese type approval
Product Details:
Weight | 12 Kg |
Communication | RS232C |
Repeatability | 0.5% FS |
Voltage | 200 to 240 V AC |
Frequency | 50 Hz |
Outside Dimension | 211(H)x365(W)x514(D)mm |
Simultaneous and continuous measurement of up to 5 components among: NOx, SO2, CO, CO2, CH4, and O2 Suited for monitoring of flue gas, combustion gas, biogas, etc.
Continuous measurement for 5 days max.
Separatable structure
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
You can check the concentration changes of all components at a glance
Easy-to-use interface
You can select a paramagnetic O2 sensor or a galvanic O2 sensor
Product Details:
Response Time | More Than Equal 15 seconds (for 90% response) |
Weight | Approx. 5 kg |
Span Drift | +-2.0% FS per week |
Repeatability | More Than Equal +-0.5% FS |
Linearity | More Than Equal +-1.0% FS |
Voltage | 264 V AC |
Frequency | 60 Hz |
Dimensions | 240 (H) x 192 (W) x 234 (D) mm |
No need for reference gas, Ideal for measuring oxygen in flammable gas
Dumbbell type paramagnetic system requires no reference gas
Suited for oxygen in flammable gas
Interference effect is negligible
Japanese type approval
Product Details:
Ambient Temperature | -5 to 45 Deg C |
Frequency | 50/60Hz |
Voltage | 100 to 240V AC |
Current | Approx. 50VA |
Ambient Humidity | Less than 90% RH |
Dimensions | 240x192x213mm |
Weight | Approx. 5kg |
Repeatability | +-1% of F.S. |
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
Product Details:
Frequency | 50/60Hz |
Voltage | 100 to 240V AC |
Repeatability | +-1%FS |
Linearity | +-2%FS |
Dimension | 470 X 354 X 211 mm |
Current | approx.50VA |
Mass | 22 Kg |
Ideal for H2, Ar, and He measurement
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
Product Details:
Material | Stainless Steel |
Ambient Temperature | -40 Deg C to +85 Deg C (non-explosion-proof version) |
Output Signal | 4-20 mA DC |
Accuracy Rating | +-0.2% |
Power Supply Voltage | 10.5-45 V DC (non-explosion-proof version) |
Suppression | -100% to +100% of URL |
Enclosure | IEC IP67, NEMA6/6p |
Product Details:
Material | PVC |
Model Name/Number | DH-109 |
Working Sample Pressure | -5.78 Kpa |
Water Sealing | 0.98 kPa |
Ambient Temperature | 1 Deg C to 40 Deg C |
Weight | Approx 0.6 Kg |
Voltage | 220 V |
Frequency | 50 Hz |
Product Details:
Chart Width | 100 mm |
Thermocouple | 12 types |
DC Voltage | +-50 mV to +-50 V |
Continuous Recording | 2 to 80 seconds |
Voltage | 240 V AC |
Frequency | 60 Hz |
Dimensions | 144 X 144 X 199 mm |
Weight | Approx. 2.1 Kg |
Product Details:
Chart Width | 100 mm |
Number of Recording Points | 1 or 2 |
Thermocouple | 12 types |
DC Voltage | +-50 mV to +-50 V |
Measurement Cycle | 0.2 seconds |
Recording Cycle | 2-40 seconds |
Display | 6-digit LED |
Voltage | 120 V AC |
Dimensions | 144 X 144 X 175 mm |
Weight | Approx. 1.2 Kg |
Product Details:
Storage Temperature | -20 Deg C to 70 Deg C |
Pipe Diameter | 200 mm |
Power Consumption | 1.5 W |
Fluid Temperature | 10 Deg C to 60 Deg C |
Humidity | RH90% |
Operating Pressure | More Than 1 MPa |
Battery Life | Approx 10 Year |
Product Details:
Weight | Approx. 500 g |
Display | 16-digit, 4-line LCD |
Battery Life | Approx. 24 hours |
Printer | Optional 24-digit printing on thermal paper |
Packaging Type | Box |
Ambient Temperature | -10 to + 50 Deg C |
Ambient Humidity | 90 % RH |
Product Details:
Weight | Approx. 6 Kg |
Chart width | 180 mm |
Number of Input Channels | 6 or 12 |
Thermocouple | 12 types |
DC Voltage | +-50 mV to +-50 V |
Measurement Cycle | 320 ms |
Voltage | 240 V AC |
Frequency | 50/60 Hz |
Dimensions | 288 x 288 x 199 mm |
Product Details:
Operating Pressure | 16 MPa, 42 MPa |
Material | Stainless Steel |
Material Grade | SS316 |
Fluid Temperature | -40 Deg C to 120 Deg C |
Process Connection | Rc1/2 |