Product Details:
Voltage | 240 V AC |
Sampling Rate | 0.2 s |
Alarm Output | 1 or 2 (option) |
Weight | approx. 100 g |
Frequency | 60 Hz |
Power consumption | More Than Equal 5 VA (at 100 V) or More Than Equal 6 VA (at 220 V) |
Display | 7-segment 4-digit LED |
Dimensions | 48 (W) x 48 (H) x 62 (D) mm |
Ambient Temperature | -10 Deg C to +55 Deg C |
Product Details:
Model Name/Number | PXR3 |
Voltage | 240 V AC |
Operating Relative Humidity | RH90% or less (non condensation) |
Weight | approx. 150 g |
Measurement cycle | more Than 0.5 s |
Resolution | 1 Deg C |
Frequency | 60 Hz |
Operating Environment | -10 Deg C to +50 Deg C |
Dimensions | 24 x 48 x 85 mm |
Product Details:
Flow Range | 50 mm |
Frequency | 50 Hz |
Voltage | 240 V |
Ambient Humidity | More Than Equal RH 90% |
Ambient Temperature | -40 Deg C to +60 Deg C |
Enclosure | IP 66 |
Power consumption | Approx. 20 VA |
Product Details:
Storage Temperature | -20 Deg C to 70 Deg C |
Pipe Diameter | 200 mm |
Power Consumption | 1.5 W |
Fluid Temperature | 10 Deg C to 60 Deg C |
Humidity | RH90% |
Operating Pressure | More Than 1 MPa |
Battery Life | Approx 10 Year |
Product Details:
Accuracy | +-1% |
Pipe Diameter | 50-1200 mm |
Fluid Temperature | -40 Deg C to 20 Deg C |
Response | 0.2 seconds |
Ambient Temperature | -20 Deg C to +55 Deg C |
Analog Output | 4-20 mA DC |
Dimension | H170 x W142 x D70 mm |
Product Details:
Zero Drift | +-1.0% FS max./week |
Repeatability | +- 0.5% FS |
Linearity | +-1.0% FS max |
Dimensions | 1710(H)x800(W)x615(D) mm |
Mass | About 300 kg |
Ambient conditions | -5 to + 40 Deg C |
Voltage | 230 V |
Frequency | 50 Hz |
Continuous monitoring of 5 components:
NOx, SO2, CO, CO2, and O2
Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Simultaneous and continuous measurement of up to 5 components
Sample switching system ensures zero-point stability
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Japanese type approval
Product Details:
Ambient Temperature | -5 to 45 Deg C |
Frequency | 50/60Hz |
Voltage | 100 to 240V AC |
Current | Approx. 50VA |
Ambient Humidity | Less than 90% RH |
Dimensions | 240x192x213mm |
Weight | Approx. 5kg |
Repeatability | +-1% of F.S. |
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
Product Details:
Frequency | 50/60Hz |
Voltage | 100 to 240V AC |
Repeatability | +-1%FS |
Linearity | +-2%FS |
Dimension | 470 X 354 X 211 mm |
Current | approx.50VA |
Mass | 22 Kg |
Ideal for H2, Ar, and He measurement
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
Product Details:
Model Name/Number | PXR3 |
Weight | approx. 150 g |
Humidity | RH90% or less (non condensation) |
Dimensions | 24 x 48 x 85 mm |
Operating Environment | -10 Deg C to +50 Deg C |
Voltage | 240 V AC |
Frequency | 60 Hz |
Resolution | 1 Deg C |
Measurement Cycle | More Than 0.5 s |
Product Details:
Power Consumption | Approx. 47 VA |
Voltage | 240 V AC |
Frequency | 50/60 Hz |
Number of Inputs | 9 or 18 points |
Measurement cycle | 100 ms |
Display | 5.7 Inch |
Recording Capacity | 2 GB max |
Indication Accuracy | +- 0.15% + 1 digit of input range |
Indication Resolution | 0.1 Deg C |
Compact front panel Up to 6 channels for thermocouples, RTD, voltage, or current input
Data saving on CompactFlash
Data viewer and parameter loader software provided as standard
Ethernet (option)
Lithium-ion battery driven version available
Quick search and display of past data
3 or 6 input channels
Product Details:
Voltage | 240 V AC |
Frequency | 60 Hz |
Power consumption | Approx. 47 VA |
Number of inputs | 9 or 18 points |
Measurement Cycle | 100 ms |
Display | 5.7 Inch |
Recording Capacity | 2 GB max. |
Open Collector Output | 18 points (option) |
Indication Resolution | 0.1 Deg C |
Product Details:
Voltage | 240 V AC |
Frequency | 50 Hz |
Power Consumption | Approx. 47 VA |
Number of inputs | 9 or 18 points |
Measurement cycle | 100 ms |
Life of backlight | 50,000 hours |
Display | 5.7 Inch |
Recording Capacity | 2 GB max |
Indication resolution | 0.1 Deg C |
Product Details:
Usage/Application | Automotive |
Accuracy | (+/-): 0.5% of reading |
Analog Output | 4-20 mA DC |
Response | 0.2 seconds |
Ambient Temperature | -20 Deg C to +55 Deg C |
Dimensions | H220 x W230 x D95 mm |
Fluid Temperature | -40 Deg C to 20 Deg C |
Flow transmitter: FSVL
Detector: FSS
Product Details:
Response Time | More Than Equal 60 s |
Power | 250 VA |
Humidity | RH90% |
Span Drift | +-2.0% FS per week |
Repeatability | +-0.5% FS (+-1% FS for 50 ppm or less) |
Linearity | +-1% FS |
Operating Environment | -5 to +45 Deg C |
Voltage | 100-240 V AC |
Frequency | 50/60 Hz |
Dimensions | 483 (H) x 177 (W) x 600 (D) mm |
Simultaneous and continuous measurement of up to 5 components among:
NO, SO2, CO2, CO, CH4, N2O, and O2
Ideal for flue gas monitoring in incinerators and industrial furnaces
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Easy-to-see LCD
Zero drift for 200 ppm range: ≤ ±1% FS per week
Product Details:
Response Time | More Than Equal 10 s (for 90% response) |
Reproducibility | +-0.5% FS |
Linearity | +-2% FS |
Voltage | 115 V AC |
Frequency | 50/60 Hz |
Gas temperature | -20 Deg C to +600 Deg C |
Gas pressure | -3 kPa to +3 kPa |
Continuous measurement of O2 in flue gas from industrial boilers or furnaces. Ideal for combustion control
Fast response
Low maintenance
A variety of inputs and outputs
Easy to operate
Product Details:
Response Time | More Than Equal 15 seconds (for 90% response) |
Weight | Approx. 5 kg |
Span Drift | +-2.0% FS per week |
Repeatability | More Than Equal +-0.5% FS |
Linearity | More Than Equal +-1.0% FS |
Voltage | 264 V AC |
Frequency | 60 Hz |
Dimensions | 240 (H) x 192 (W) x 234 (D) mm |
No need for reference gas, Ideal for measuring oxygen in flammable gas
Dumbbell type paramagnetic system requires no reference gas
Suited for oxygen in flammable gas
Interference effect is negligible
Japanese type approval
Product Details:
Material | Stainless Steel |
Ambient Temperature | -40 Deg C to +85 Deg C (non-explosion-proof version) |
Output Signal | 4-20 mA DC |
Accuracy Rating | +-0.2% |
Power Supply Voltage | 10.5-45 V DC (non-explosion-proof version) |
Suppression | -100% to +100% of URL |
Enclosure | IEC IP67, NEMA6/6p |