Controllers Timers And Counters

Manufacturer of a wide range of products which include digital counters timers.
  • Digital Counters Timers
  • Digital Counters Timers
  • Digital Counters Timers
  • Digital Counters Timers
Digital Counters Timers

Digital Counters Timers

Rs 2,000  / PieceGet Best Price

Product Brochure

Model Name/NumberBL99
Size96 X 96 cm
Operating Temp.0-55 Deg C
Accuracy0.05 % Full Scale
Memory RetentionUp to 10 Year
Sensor Supply12 V DC (+-10%) @ 30 mA
Humidity95% RN (Non Condensing)
BrandI Therm
Supply90 to 270 V AC
MountingPanel
Safety Instruction:
  • This controller is meant for Batch & Length counter applications. It is important to read the manual prior to installing or commissioning of controller. All safety related instruction appearing in this manual must be followed to ensure safety of the operating personnel as well as the instrument.
General:
  • The controller must be configured correctly for intendedoperation. Incorrect configuration could result in damage to theequipment or the process under control or it may lead personnelinjury.
  • The controller is generally part of control panel and in such acase the terminals should not remain accessible to the user afterinstallation.

Mechanical:
  • The Controller in its installed state must not come in close proximity to any corrosive/combustible gases, caustic vapors, oils, steam or any other process by products.
  • The Controller in its installed state should not be exposed to carbon dust, salt air, direct sunlight or radiant heat.
  • Ambient temperature and relative humidity surrounding the controller must not exceed the maximum specified limit for proper operation of the controller.
  • The controller in its installed state must be protected against excessive electrostatic or electromagnetic interferences.
  • Ventilation holes provided on the chassis of the instrument are meant for thermal dissipation hence should not be obstructed in the panel.

Electrical:
  • The controller must be wired as per wiring diagram & it must comply with local electrical regulation.
  • Care must be taken not to connect AC supplies to low voltage sensor input.
  • Circuit breaker or mains s/w with fuse (275V/1A) must be installed between power supply and supply terminals to protect the controller from any possible damage due to high voltage surges of extended duration.
  • Circuit breaker and appropriate fuses must be used for driving high voltage loads to protect the controller from any possible damage due to short circuit on loads.
  • To minimize pickup of electrical noise, the wiring for low voltage DC and sensor input must be routed away from high current power cables. Where it is impractical to do this, use shielded ground at both ends.
  • The controller should not be wired to a 3-Phase supply with unearthed star connection. Under fault condition such supply could rise above 264 VAC which will damage the controller.
  • The Electrical noise generated by switching inductive loads might create momentary Fluctuation in display, alarm latch up, data loss or permanent damage to the instrument. To reduce this use snubber circuit across the load.